Bengaluru: Karnataka’s Legal Metrology Department has issued a show-cause notice to the officer in charge of the Indian Oil Corporation Limited (IOCL) terminal at Devanagonthi in Bengaluru after its mass flow meters were found delivering more ethanol and less petrol than they measured, Food and Civil Supplies Minister Rizwan Arshad said.
Arshad said that after the state government exposed over-blending of ethanol in petrol beyond the prescribed E20 limit, the Legal Metrology Department has begun inspecting the terminals of oil marketing companies (OMCs) where the blending is carried out.

The notice, dated November 25, is from the Joint Controller of Legal Metrology, Bangalore and Mysore Division, Mysuru, and is addressed to the Deputy General Manager and Terminal In-charge of the IOCL terminal. It says the mass flow meters at the terminal were inspected on November 25 and tested using a verified master proving measure.
The notice records three discrepancies. At Bay No. 9, a mass flow meter fitted with a Bach control unit delivered 14 litres of ethanol in excess for every 3,000 litres measured, and the same meter short-delivered 4 and 6 litres of motor gasoline for every 3,000 litres measured. At Bay No. 4, another mass flow meter delivered 3 litres of ethanol in excess for every 3,000 litres measured.

The department says the errors are beyond the permissible limits under the Legal Metrology Act and rules, may violate the statutory requirements for using weighing and measuring instruments, and can affect consumers, dealers and other stakeholders. It has asked IOCL to show cause why legal and departmental action should not be taken against the terminal and the persons responsible for operating and maintaining the measuring systems.

IOCL has been asked to explain the reasons for the discrepancies, the steps taken to ensure the accuracy of the meters and the Bach control units, including its latest calibration and maintenance records, and the corrective measures it proposes. It must submit a written reply with verification certificates, calibration records and maintenance records within seven days of receiving the notice.
The notice also directs that the measuring systems concerned must not be used for further commercial transactions until their accuracy and compliance with the law are established. If a satisfactory explanation is not given in time, it warns, further action can follow under the Legal Metrology Act, 2009, without further notice.